Safety glazing

Certification and the code

Is switchable glass safety glazing?

The laminated products are: PriWatt switchable glass is certified under SGCC 9894, made from low-iron glass that is heat-treated or fully tempered, and laminated. That is the answer for a panel PriWatt manufactures.

It is not the answer for self-adhesive film applied to glass that is already in the building — and the difference decides whether a door, a shower enclosure or a railing is compliant. The rest of this page is that distinction, and where the code asks the question in the first place.

Where it is required

The openings the code calls hazardous locations

Safety glazing is not a whole-building requirement. The building code names specific locations where glass is likely to be walked into, fallen against or leaned on, and requires safety glazing in each of them. Every one of these is somewhere switchable glass is regularly specified:

LocationWhy the code names itOn this site
Glazing in doorsSomebody walks into it. Swinging, sliding and folding leaves alikeDoors
Glazing beside a doorThe panel next to a door is mistaken for the openingDoors
Wet enclosuresShowers, bathtubs, steam rooms and pool surrounds — a fall onto glass, on a wet floorShower enclosures
Guards and railingsThe glass is the barrier. It is holding people back from a dropRailings and balustrades
Glazing near stairs, landings and rampsA fall arrives at the glass rather than at the floorRailings and balustrades
Large panels close to the floorA low, wide pane reads as an opening at walking speedDoors, partitions
Sloped and overhead glazingGoverned separately, and by its own provisions rather than theseSkylights and overhead

Which provisions apply to a particular opening depends on the code edition adopted locally and on the authority having jurisdiction. What is portable from project to project is the certificate, and that is what a submittal carries.

What SGCC 9894 means

A certification, not a test result

The Safety Glazing Certification Council is a third-party body. Certification is not a single passed test — it requires submission to approved independent laboratories, impact and breakage testing, demonstrated reduction in injury risk, and continuing compliance through ongoing inspection and audit. A certificate that is current means the product is still being checked.

ANSI Z97.1

The American standard for safety glazing materials used in buildings: impact performance and how the glazing behaves when it fails.

CPSC 16 CFR 1201

The US federal safety standard for architectural glazing materials — a regulation rather than a voluntary standard, which is why it is the one cited in disputes.

CAN/CGSB 12.1

The Canadian standard for tempered and laminated safety glass, which matters on the projects delivered across the border.

And separately, UL E514182

Safety glazing says nothing about the electrical system. That is a different file, evaluated by UL Solutions, and a switchable panel needs both.

Read this before specifying film

Film does not make existing glass into safety glazing

Self-adhesive switchable film is applied to glazing that is already in the building. The film is not the glazing, and applying it does not change what the pane underneath is certified as.

So in a hazardous location the question is about the existing glass: was it safety glazing when it was installed, and is there a record of it? In a building that was built to code and has not been altered, usually yes — a door glazed to code is still glazed to code with film on it. In a building where the glazing has been changed, or where nobody can say what was installed, that is a question to answer before the film is ordered rather than after it is applied.

Laminated switchable glassFilm on existing glazing
Safety glazing certificationSGCC 9894, on the panel PriWatt makesA question about the glass that is already there
The glassLow iron, heat-treated or fully temperedWhatever was installed
What the submittal carriesThe certificate, for this productThe original glazing record, if one exists
Where it suits a hazardous locationMade for itWhere the existing glass is already compliant

This is the one place where the cheaper route is not simply the cheaper route. The trade-offs between the two are set out in full on smart glass or smart film.

Where this comes up, by format

Doors

A door and the panels beside it are hazardous locations whether they switch or not.

Shower enclosures

A wet enclosure, and the one room where normal mode is the correct specification.

Railings and balustrades

The glass is the barrier. Certification is one half; the structural design is the other.

Skylights and overhead

Governed by the sloped-glazing provisions rather than by these, and reviewed with the AHJ.

Common questions

The laminated products are, under SGCC 9894. They are made from low-iron glass, heat-treated or fully tempered, and laminated around the switchable layer. The certificate is supplied in full with the submittal.

No. Film is applied to glazing that is already installed, and it does not change what that pane is certified as. In a hazardous location the question is whether the existing glass was safety glazing to begin with — which in a building built to code and unaltered it usually was, but it is worth confirming before ordering rather than after applying.

ANSI Z97.1, the US federal regulation CPSC 16 CFR 1201, and CAN/CGSB 12.1 in Canada. Certification is not a single passed test: it requires independent laboratory testing, demonstrated reduction in injury risk, and ongoing inspection and audit.

In the locations it names as hazardous — glazing in doors and beside them, wet enclosures such as showers and pool surrounds, guards and railings, glazing near stairs and ramps, and large panels close to the floor. Sloped and overhead glazing is governed separately. Which provisions apply to a given opening is set by the code edition adopted locally and by the authority having jurisdiction.

No, and the two are often confused. Safety glazing is about what the glass does when somebody hits it. Fire-rated glazing is about holding a fire, and switchable glass is not fire-rated glazing. What it does have is independent material fire-performance data — smoke, heat release and toxicity — set out separately.

No. SGCC covers the glazing; the electrical system is evaluated under UL file E514182. A switchable panel needs both, and both certificates go into the submittal.

Reading beside this

No SGCC certification? You are taking a risk

The argument rather than the reference: what an uncertified panel exposes, and four questions to ask any supplier.

Fire, smoke and toxicity

Tested at Intertek against NFPA 130 — and why a material fire test is not a fire rating.

Patents and certifications

UL E514182, SGCC 9894 and the patents behind the busbar anchoring, with the documents.

Send the opening and the location