Architects and designers

Specification support

Specify it with the numbers in front of you

Switchable glass reaches most drawings as the words "smart glass" and reaches the site as whatever the contractor could source. The gap between those two is where projects go wrong. PriWatt manufactures the product. The answers come from the plant, not from a distributor reading a datasheet.


Manufactured in the USA · UL Recognized Components · SGCC Safety Glazing · Custom fabrication
What we do for a project

Before it is drawn, and after

Samples in hand

Samples for qualified projects, because a client who has switched a panel themselves asks better questions than one who has seen a photograph of one.

Technical consultation

Which mode the room wants, which format the building programme allows, and what the panel does about acoustics, solar gain and the edge condition.

Shop drawings before fabrication

Every project starts with a technical review. Sizes, cut-outs, the wiring exit and the tolerances are agreed while they are still drawings.

A manufacturer to call

A curve, a railing, a cleanroom viewing panel. When the detail is unusual, the answer comes from the people who would have to make it.

The six lines that make it buildable

Switchable glass arrives on drawings underspecified more often than it arrives overspecified. These are the lines that decide whether what is delivered is what was drawn:

  • The mode. State it as the condition the panel holds with no power, never as a product name
  • The format: laminated switchable glass, or self-adhesive film applied to existing glazing
  • Panel sizes and shapes, with the cut-outs the hardware needs. The maximum is 143 in tall, and 57 to 72 in wide depending on the product
  • The transformer and the control, sized to the run and named
  • The edge condition: how the busbar is anchored and where the wiring leaves the panel
  • Certification you can cite: UL file E514182, SGCC 9894

Add an acoustic figure where the room needs one. It belongs to the whole glass make-up, not to the liquid crystal, so it is quoted per build-up. A switchable partition at a Toronto investment office was specified at Rw 35–36 dB, and the same panel doubles as a rear-projection screen.

Reading before you specify

PDLC against PNLC, with the numbers

Haze, privacy, switching, voltage, power draw and maximum panel, side by side.

Reverse mode, in full

What changes when the glass is clear with no power, and the rooms it is wrong for.

Inside an insulated unit

What a switchable layer changes on a facade: solar gain, HVAC load, what comes off the elevation.

Cost per square foot

Ranges for film and glass, what moves the number, and what is quoted separately.

Patents and certifications

UL E514182, SGCC 9894 and the patents behind the busbar anchoring.

Every measured value

Optical, electrical and physical data for all six products, in one table, stated by optical state.

Fire, smoke and toxicity

Tested at Intertek against NFPA 130. The numbers, and what a material test does not mean.

Where it is made

The bill of materials, and what Buy American, TAA and BABA each actually ask of it.

Doors, showers, rooflights, railings

What each one changes about the wiring, the edge, the code, and the state the panel holds unpowered.

Sixty-six projects in service

Offices, clinics, museums, studios, railings, a yacht and a cleanroom. The constraint each one had.

Not quite what you do?

Installers and glaziers

Take on switchable work in your city — trained, certified, and first call for projects in your area.

Window and door manufacturers

Offer a switchable option inside your own line, built to your sizes and your hardware.

Glass and IGU fabricators

Add a switchable layer to what you already build, with the edge detail solved.

The specification package

Fourteen documents, sent to your inbox

The certificates, the three-part specification, the independent test reports, four CAD details as PDF and editable DXF, and the electrical installation guide. Ask for the ones the project needs and they arrive as attachments — not as a link that expires before the drawing is issued.

DocumentWhat it covers
CSI specification — 08 88 00The three-part spec, ready to edit into a project manual
UL certification — file E514182The electrical system, evaluated by UL Solutions
SGCC certificate 9894Safety glazing certification for the laminated products
Acoustic performance — STC 37, OITC 33Airborne sound transmission measured to ASTM E90 at Riverbank
ASTM E662 · ASTM E1354Smoke density, heat release and smoke — tested at Intertek against NFPA 130
Bombardier SMP 800-CToxic gas generation under combustion
CAD — laminated glass make-upIsometric, section, glass thickness table and the film types — PDF and editable DXF
CAD — film on existing glazingRetrofit assembly, film section with layer thicknesses, both busbar types — PDF and DXF
CAD — wiring schematicSupply, transformer and panels, with the NFPA 70 requirements — PDF and DXF
CAD — maximum panel sizesDimensioned size limits, per panel type — PDF and DXF
Isolation transformersRatings and dimensions for the units that drive the panels
Electrical connection guideSupply, busbar locations, panel chaining, wiring diagrams and the sixteen installation requirements
PNLC reverse glass brochureThe reverse-mode product and where it is specified

Request the documents

Tell us who you are and which documents the project needs. They are sent to the address you give. If you would rather talk the specification through first, book a technical call and pick the time yourself.

Links are sent to the address you give and stay valid for seven days.

Which documents

We use your details only to answer this enquiry.

Samples and a technical consultation are available for qualified projects. Call 1-866-PRIWATT (1-866-774-9288), or send a message.